  5. Gypsum Board Shear Values

Gypsum Board Shear Values

Shear values for parallel application exceed those for perpendicular application, 3. Shear values for ⅝ in. (15.9 mm) gypsum board exceed those for ½ in. (12.7 mm) gypsum board, 4. Shear values increase with closer spacing of perimeter fasteners, and 5. When compared to other shear test results, shear values for screws are higher than for nails.

Get Price

Our products

We provide quality and efficient solutions to our global customers.From China, serving the world.

More Details

As for the products you want to know, we will give you a detailed introduction.

  • SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM

    SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM

    Shear values for parallel application exceed those for perpendicular application, 3. Shear values for 5/8" gypsum board exceed those for ½" gypsum board, 4. Shear values increase with closer spacing of perimeter fasteners, and 5. When compared to other shear test results, she ar values for screws are higher than for nails.

    Click to view
  • GA2292018 Shear Values for Screw Application of Gypsum

    GA2292018 Shear Values for Screw Application of Gypsum

    Apr 11, 2019 · GA-229-2018 Shear Values for Screw Application of Gypsum Board On Walls Supplement to Construction Dimensions Magazine Gypsumation provides essential gypsum board information to A/E/C professionals, contractors, and code officials twice annually.

    Click to view
  • SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM

    SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM

    Shear values for parallel application exceed those for perpendicular application, 3. Shear values for ⅝ in. (15.9 mm) gypsum board exceed those for ½ in. (12.7 mm) gypsum board, 4. Shear values increase with closer spacing of perimeter fasteners, and 5. When compared to other shear test results, shear values for screws are higher than for nails.

    Click to view
  • Gypsum Sheathing 800NATIONAL

    Gypsum Sheathing 800NATIONAL

    Shear values for all gypsum panels, including gypsum sheathing, are defined in GA-229, Shear Values for Screw Application of Gypsum Board on Walls at: gypsum.org .

    Click to view
  • Gold Bond BRAND Gypsum Sheathing

    Gold Bond BRAND Gypsum Sheathing

    Shear values for all gypsum panels, including gypsum sheathing, are defined in GA-229, Shear Values for Screw Application of Gypsum Board on Walls at: gypsum.org .

    Click to view
  • Gypsum shearwalls. Nails or screws? | StructuralIntl

    Gypsum shearwalls. Nails or screws? | StructuralIntl

    Apr 08, 2003 · We were primarily interested in whether or not the gypsum values with 50% zone 4 reduction were appropriate when compared to the plywood values. The nail sizes, nailing pattern, blocking, etc. were taken directly from the code and were not necessarily an attempt to model any current construction method.

    Click to view
  • GYPSUM BOARD SHEATING FOR WOODEN STUDS  Moment

    GYPSUM BOARD SHEATING FOR WOODEN STUDS Moment

    Apr 21, 2003 · GYPSUM BOARD SHEATING FOR WOODEN STUDS. No, its not in a seismic region but the wind speed is ranging from 80 - 100 mph. On higher floor, based on calculations, have shear loads lesser than what boo1 had given above.The shear capacity of 15/32 plywood sheathing with 10d nails at …

    Click to view
  • SureBoard For Shear | Steel Framing

    SureBoard For Shear | Steel Framing

    Sure-Board® For Shear Sure-Board® is a patented revolutionary product designed for today’s ever changing construction industry. Developed out of the need for a stronger, longer lasting and more reliable shear wall panel, Sure-Board® is the best choice for Engineers, Architects, and Contractors alike.

    Click to view
  • SureBoard  Shear Strength Shear Value | Sheathing for

    SureBoard Shear Strength Shear Value | Sheathing for

    Sure-Board® Series 200B – Blast and Ballistics is the preferred non-combustible blast and ballistic wall designed specifically for Engineers and Architects. Sure-Board® Series 200S was used on the first 6-story CFS building that showed no signs of structural damage after being tested on UCSD’s shake table.

    Click to view
  • Gypsum shearwalls. Nails or screws? | StructuralIntl

    Gypsum shearwalls. Nails or screws? | StructuralIntl

    Apr 08, 2003 · We were not yet looking at capacities of new assemblies but trying to verify the code established values in chapters 25 and 47 of the 1994 UBC (current edition at the time of the original tests). We were primarily interested in whether or not the gypsum values with 50% zone 4 reduction were appropriate when compared to the plywood values.

    Click to view
  • 810 FIRST STREET NE 510 WASHINGTON DC 20002 SHEAR

    810 FIRST STREET NE 510 WASHINGTON DC 20002 SHEAR

    2. Shear values for parallel application exceed those for perpendicular application, 3. Shear values for 5/ 8" gypsum board exceed those for ½" gypsum board, 4. Shear values increase with closer spacing of perimeter fasteners, and 5. When compared to other shear …

    Click to view
  • Technical Data Shear Resistance Classications for

    Technical Data Shear Resistance Classications for

    Ceiling Diaphragm Span Between Shear Walls: 28 ft. Ceiling Application C-004 5/16 in. S HEETROCK MH Brand Predecorated Ceiling Board (L UNAR ) or 3/8, 1/2, 5/8 in. S MH Brand (Staples) Gypsum Panels or Ceiling Boards fastened to wood roof framing spaced 16 in. o.c. with No. 16 ga. staples

    Click to view
  • shear value for screw into drywall?  Structural

    shear value for screw into drywall? Structural

    Dec 21, 2007 · If so, the IBC in the wood section has values for shear for gyp board and sheathing. I believe it is Table 2306.4.5. It includes shear values for screws, nails, and staples.

    Click to view
  • CHAPTER 25 GYPSUM BOARD GYPSUM PANEL PRODUCTS AND

    CHAPTER 25 GYPSUM BOARD GYPSUM PANEL PRODUCTS AND

    Wood-frame shear walls sheathed with gypsum board, gypsum panel products or lath and plaster shall be designed and constructed in accordance with Section 2306.3 and …

    Click to view
  • Diaphragm Basics Using SDPWS

    Diaphragm Basics Using SDPWS

    permitted to resist horizontal forces using the allowable shear capacities set forth in Table 2306.2.1(1) or 2306.2.1(2). The allowable shear capacities in Tables 2306.2.1(1) and 2306.2.1(2) are permitted to be increased 40 percent for wind design. 2306.2.2 Single diagonally sheathed lumber diaphragms. Single

    Click to view
  • Shear Resistance of Walls with Steel Studs

    Shear Resistance of Walls with Steel Studs

    The shear resistance test load is either the ultimate load, the code deflection load, or. the damage threshold load. The code deflection load is equivalent to a test load producing. 0.5 inch total deflection in 8 feet of wall panel height.

    Click to view
  • ColdFormed Steel Shear Wall Design

    ColdFormed Steel Shear Wall Design

    Nominal Static Shear Strength with OSB Sheathing as a Function of Screw Spacing and Aspect Ratio basis, the shear strength of panels with an aspect ratio of 4:1 varies from 95 to 59 percent (depending on screw spacing) of that of panels with an aspect ratio of 2:1 or 1:1. The lower shear strength percentages occurred in those cases where the wall

    Click to view
  • A Code History  Simpson StrongTie Structural Engineering

    A Code History Simpson StrongTie Structural Engineering

    CFS Framed Shear Walls – A Code History. It adds additional shear strength values for steel-sheet shear walls and limits diagonal strap braced walls to a 2:1 aspect ratio unless the chord studs are designed for the end moments. The seismic response modification coefficient, R, is currently 6.5 for wood and steel sheet-sheathed assemblies,...

    Click to view
  • SureBoard  Shear Strength Shear Value | Sheathing for

    SureBoard Shear Strength Shear Value | Sheathing for

    Sure-Board® Series 200B – Blast and Ballistics is the preferred non-combustible blast and ballistic wall designed specifically for Engineers and Architects. Sure-Board® Series 200S was used on the first 6-story CFS building that showed no signs of structural damage after being tested on UCSD’s shake table.

    Click to view
  • 2015 Special Design Provisions for Wind and Seismic

    2015 Special Design Provisions for Wind and Seismic

    COLLECTOR. A diaphragm or shear wall boundary element parallel to the applied load that collects and transfers diaphragm shear forces to the vertical force-resisting elements or distributes forces within the dia-phragm or shear wall. COMPOSITE PANELS. A wood structural panel comprised of wood veneer and reconstituted wood-

    Click to view
  • ExtErior Gypsum shEathinG

    ExtErior Gypsum shEathinG

    Shear Values - Shear values for wind or seismic forces based on racking test conducted in accordance with ASTM E 72 on 4’ (1219mm) wide Exterior Gypsum Sheath - ing applied parallel to framing. Where wind or seismic forces require shear walls to resist these lateral forces, most building codes provide allowable shear values for walls having ...

    Click to view
  • San Jose Seismic Retrofit Performance of Drywall

    San Jose Seismic Retrofit Performance of Drywall

    Shear walls sheathed with portland cement plaster, gypsum lath, gypsum sheathing or gypsum board shall not be used to resist seismic forces in structures assigned to Seismic Design Category D. The green and red arrows are in the THICKNESS OF MATERIAL column for drywall that is ½ inch thick.

    Click to view
  • GA Publications AtAGlance  Gypsum Association

    GA Publications AtAGlance Gypsum Association

    GA-229-2018 Shear Values for Screw Application of Gypsum Board On Walls Tests conducted in accordance with ASTM E72 determine average ultimate shear values of gypsum …

    Click to view
  • National Gypsum Gold Bond BRAND eXP Sheathing

    National Gypsum Gold Bond BRAND eXP Sheathing

    Code for One- and Two-Family Dwellings [IRC]). Shear values for all gypsum panels, including gypsum sheathing, are deined in GA-229-08, Shear Values for Screw Application of Gypsum Board on Walls. MOLD AND MILDEW RESISTANCE eXP Sheathing was designed to provide extra protection against mold and mildew. When tested by an independent laboratory,

    Click to view
  • ExtErior Gypsum shEathinG

    ExtErior Gypsum shEathinG

    Where shear values are not required, Exterior Gypsum Sheathing 4’ (1219mm) wide shall be permitted to be applied parallel or perpendicular to framing. Exterior Gypsum Sheathing applied perpendicular (horizontal) to framing shall be covered with a weather-resistant barrier (#15 felt or equivalent), or horizontal joints shall be

    Click to view
  • Drywall Screws | StructuralIntl Bldg and Residl Codes

    Drywall Screws | StructuralIntl Bldg and Residl Codes

    Feb 27, 2002 · Yes there are Evaluation Reports and UL listings that have values using drywall screws in lieu of nails. They are specific, and proprietary. You can contact the manufacturer of the gypsum wallboard you are using and find out the values.they wont be much higher than those in the code book for nails since it is the wallboard that fails not the fasteners.

    Click to view
  • CHAPTER 25 GYPSUM BOARD GYPSUM PANEL PRODUCTS AND

    CHAPTER 25 GYPSUM BOARD GYPSUM PANEL PRODUCTS AND

    Cold-formed steel-frame shear walls sheathed with gypsum board or gypsum panel products and constructed in accordance with the materials and provisions of Section 2211.6 are permitted to resist wind and seismic loads.

    Click to view
  • Installation of Interior Gypsum Board Finish | SBC Magazine

    Installation of Interior Gypsum Board Finish | SBC Magazine

    Average Ultimate Shear Capacity of 1/2" Gypsum Board Walls. ... If the values are prescribed in the code it is the law and, as such, is relied upon in the market as accurate. As a consequence, it is reasonable to assume the law developers would seek to fix any inaccurate values. This is particularly true if empirical evidence shows the law is ...

    Click to view
  • CHAPTER 25 GYPSUM BOARD AND PLASTER | 2012 International

    CHAPTER 25 GYPSUM BOARD AND PLASTER | 2012 International

    Wood-framed shear walls sheathed with gypsum board, lath and plaster shall be designed and constructed in accordance with Section 2306.3 and are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7.

    Click to view