The red line is the KBr pellet method spectrum and the blue line is the KCl pellet method spectrum. The shapes of the spectra are clearly different near 3000 cm -1 . Other differences are also apparent in the low-wavenumber region.

Get Price

Our products

We provide quality and efficient solutions to our global customers.From China, serving the world.

More Details

As for the products you want to know, we will give you a detailed introduction.

  • KBr pellet faults | Spectroscopy Guides  Specac

    KBr pellet faults | Spectroscopy Guides Specac

    Jun 12, 2017 · KBr pellet fault Cause of KBr pellet fault Fix for KBr pellet fault; 1) Sample KBr pellet not clear. Lacks optical clarity. Sample damp, contaminated KBr powder or insufficient pressure when pressing. Dry the sample powder or sample and increase the pressure via the hydraulic pellet press. 2) Sample KBr pellet clear, but shows opaque spots.

    Click to view
  • How to prepare IR samples?  NUANCE Center

    How to prepare IR samples? NUANCE Center

    Press the powder for 2 minutes to form a pellet. A good KBr pellet is thin and transparent. Opaque pellets give poor spectra, because little infrared beam passes through them. White spots in a pellet indicate that the powder is not ground well enough, or is not dispersed properly in the pellets.

    Click to view
  • KBr Pellet Preparation for IR Spectroscopy using Hydraulic

    KBr Pellet Preparation for IR Spectroscopy using Hydraulic

    May 15, 2019 · KBr Pellet Preparation or sample preparation the most important part for IR spectroscopy. Sample should be transparent to IR radiations so it allows the radiations to pass through them. So salts like KBr, NaCl, AgCl are used for mixing of sample in order to obtain the accurate IR spectrum of a sample with sharp peaks, good intensity with high resolution.

    Click to view
  • Measurement Methods for Powder Samples : SHIMADZU

    Measurement Methods for Powder Samples : SHIMADZU

    KBr Pellet Method This method exploits the property that alkali halides become plastic when subjected to pressure and form a sheet that is transparent in the infrared region. Potassium bromide (KBr) is the commonest alkali halide used in the pellets.

    Click to view
  • why KBr is used in FTIR SPECTROSCOPY and why is it

    why KBr is used in FTIR SPECTROSCOPY and why is it

    Potassium bromide (KBr) is the commonest alkali halide used in the pellets. Cesium iodide (CsI) may also be used to measure the infrared spectrum in the 400 to 250 cm-1 low-wavenumber region. The preparation method for 13 mm-diameter pellets is described below.

    Click to view
  • IR SPECTROSCOPY IS A WELL ESTABLISHED TECHNIQUE cm1

    IR SPECTROSCOPY IS A WELL ESTABLISHED TECHNIQUE cm1

    7 mm diameter KBr sample pellets with a 2T Mini-Pellet press. The Specac Advanced Solid Pack, with its 13 mm Evacuable Pellet Die and a 15T Manual Hydraulic Press, was used to make the 13 mm diameter KBr pellets. Discussion The transmission spectra for 7 and 13 mm pellets of Buscopan, Levothyroxine and Omeprazole are

    Click to view
  • Why we use KBr in FTIR?  ResearchGate

    Why we use KBr in FTIR? ResearchGate

    Potassium bromide (KBr) is the commonest alkali halide used in the pellets. Cesium iodide (CsI) may also be used to measure the infrared spectrum in the 400 to 250 cm-1 low-wavenumber region.

    Click to view
  • Solid Sampling  KBr Presses  Gemini Launch Pad

    Solid Sampling KBr Presses Gemini Launch Pad

    Evacuable KBr & Briquetting Pellet Dies The 3mm to 19mm dies are used primarily for KBr pellets for transmission analysis by IR spectroscopy, while the larger dies are most commonly used for producing briquettes for XRF spectroscopy.

    Click to view
  • Pellet Making  PIKE Technologies

    Pellet Making PIKE Technologies

    Pellet analysis is still one of the most popular, inexpensive and reliable transmission techniques in FTIR spectroscopy. PIKE Technologies offers a comprehensive selection of tools and materials for preparation of high quality pellets for this well established method.

    Click to view
  • Quick Press KBr pellet kit | SigmaAldrich

    Quick Press KBr pellet kit | SigmaAldrich

    This hand press is for making transparent KBr pellets (discs). The pellet is formed using only the pressure of a firm handshake applied steadily to the handle. Kit includes a die set for making 7mm diam. pellets. • Die sets made of hardened nickel based alloy. • Anvil faces are optically polished. • Optional 2 and 4mm die sets and collars.

    Click to view
  • KBr Pellet Preparation for IR Spectroscopy using Hydraulic

    KBr Pellet Preparation for IR Spectroscopy using Hydraulic

    May 15, 2019 · For powdered samples one of the way is to disperse it in Infrared Transparent medium such as Potassium Bromide (KBr) by pressing it into disc. Typical Conditions for KBr sample preparation: 100:1 Kbr to sample ratio ( by weight) 13 mm Pellet Die. 10 ton pressing load. While 7 mm pellet for FTIR applications for as little a 2 tons.

    Click to view
  • Preparation of a KBr pellet  YouTube

    Preparation of a KBr pellet YouTube

    Jan 18, 2010 · A guide to the preparation of a KBr pellet to be used in IR spec. This feature is not available right now. Please try again later.

    Click to view
  • Kbr Pellet | Spectrum

    Kbr Pellet | Spectrum

    Related Categories: Kbr | Potassium Bromide | Ftir. PerkinElmer KBr Evacuable Die The Evacuable Potassium Bromide Die will prepare 13 mm diameter pellets of the highest quality and clarity. The pellet is formed inside an evacuated chamber and pressed between a highly polished anvil and plunger.

    Click to view
  • FTIR Procedure  Missouri ST

    FTIR Procedure Missouri ST

    KBr Pellet procedure for solid samples Take about 1/8” of the solid sample on a microspatula and about 0.25-0.50 teaspoons of KBr. Mix thoroughly in a mortar while grinding with the pestle. If the sample is in large crystals, grind the sample separately before adding KBr. …

    Click to view
  • Cary 630 FTIR Sampling Accessories | Agilent

    Cary 630 FTIR Sampling Accessories | Agilent

    Solids are analyzed in a pressed KBr pellet, a nujol mull, or evaporation onto salt plates; liquids are measured with a traditional sealed or demountable cell and gases can be …

    Click to view
  • SILICA Respirable Crystalline by IR KBr pellet 7602

    SILICA Respirable Crystalline by IR KBr pellet 7602

    to a 13-mm evacuable pellet die using glassine paper and camel’s hair brush. Place the die into the laboratory press and apply requisite pressure to prepare the sample KBr pellet. Weigh the finished pellet to the nearest 0.1 mg and calculate the ratio of the weight of …

    Click to view
  • KBr | SigmaAldrich

    KBr | SigmaAldrich

    E-Z ™ Quick Table Top KBr Pellet Press w/2mm, 4mm and 7mm die set. 1 Product Result | Match Criteria: Product Name, Description

    Click to view
  • FTIR Spectra Of KBr

    FTIR Spectra Of KBr

    I put KBr powder in oven for drying . after this process i get FT-IR spectra of pure KBr but again water and CO2 peaks have seen in spectrum AND in other materials also this 2 peaks have seen .

    Click to view
  • IR spectra using a KBr disc or a diamond ATR. Which is

    IR spectra using a KBr disc or a diamond ATR. Which is

    Feb 09, 2014 · However, the KBr disc method gives greater resolution than the ATR. Youll also find that the ATR method gives a lot of interference below 600 wavenumbers, which results in it only being practical to measure down to 650 cm-1, whereas with the KBr disc method one can go down to 450 cm-1.

    Click to view
  • FTIR Accessories | Thermo Fisher Scientific  US

    FTIR Accessories | Thermo Fisher Scientific US

    FTIR Accessories for Liquid Sample Analysis Attenuated Total Reflection (ATR) is a preferred method for liquid analysis because it simply requires a drop of liquid to be placed on a crystal. Our ATR accessories optimize the material identification and verification capabilities of Thermo Scientific FTIR spectrometers for a variety of liquid ...

    Click to view
  • Transmission | JASCO

    Transmission | JASCO

    Micro Sealed Liquid Cell. Micro KBr Pellet Die Three types of die kits are available to form micro pellets of 2, 3 and 5 mm diameter. The average quantity of sample required is 50 µg for the 3 mm pellets die. A mini press or hydraulic press is required when forming pellets. In order to avoid to rust, coated pellet die kits of 5 and 3 mm pellet die are available.

    Click to view
  • Preparing Solid IR Pellets  YouTube

    Preparing Solid IR Pellets YouTube

    Sep 14, 2010 · Preparing a pellet is necessary for analyzing a solid sample by IR. How To Use Your Smartphone to See Through Walls! Supermans X-ray Vision Challenge - …

    Click to view
  • Quantitative Analysis of Powdered Solids with FTIRATR

    Quantitative Analysis of Powdered Solids with FTIRATR

    FT-IR spectra of 64 scans at 4 cm-1 resolution were coadded and averaged to obtain the single-beam background and sample micro-ATR spectra. 32 scans at 4cm-1 resolution were used to collect the single-beam background and KBr pellet transmission spectra.

    Click to view
  • Quick Press KBr pellet kit | SigmaAldrich

    Quick Press KBr pellet kit | SigmaAldrich

    General description 1. KBr powder/sample matrix is poured into the hole in the SS collar into which the shorter... 2. The longer second anvil is then inserted in the collar and the assembly is placed in... 3. Pressure is applied to the sample by squeezing the handle. 4. When the anvils are ...

    Click to view
  • Why might a KBr pellet be used in IR spectroscopy

    Why might a KBr pellet be used in IR spectroscopy

    Feb 03, 2016 · Socratic Meta Featured Answers Topics Why might a #"KBr"# pellet be used in IR spectroscopy? Organic Chemistry Infrared Spectroscopy Infrared Spectroscopy. 1 Answer Truong-Son N. Feb 3, 2016 Consider the main point of IR. What youre doing in IR spectroscopy is disturbing the motion of molecules with resonant frequencies to make them stretch ...

    Click to view
  • IR  FTIR Accessories  Hydraulic Pellet Press Automatic

    IR FTIR Accessories Hydraulic Pellet Press Automatic

    KBR Die Set. Most commonly used Die for IR/FTIR for solid sampling of 13 mm pallet size consist of Anvil & Plunger, Top & Bottom Die Port. Extractor Ring, O ring. Other sires like 10mm, 20mm also available. We are leading manufacturer and supplier of KBR die set. Most commonly used die set for IR/FTIR for solid sampling of 13mm pallet size.

    Click to view
  • Solid Sampling and KBr Pellet Presses On International

    Solid Sampling and KBr Pellet Presses On International

    The 15 and 20 ton E-Z Press™ will handle a variety of lab applications, including pressing KBr pellets for FTIR spectroscopy and briquetting samples for XRF spectroscopy. Ports in the walls of the press frame allow access for vacuum lines and electrical cords to the area between the platens, which enables use of the press with evacuable dies and heated platens.

    Click to view
  • Evacuable Pellet Press for 13 mm pellets  PIKE Technologies

    Evacuable Pellet Press for 13 mm pellets PIKE Technologies

    The PIKE Technologies Evacuable Pellet Press is the preferred accessory for making pellets for FTIR analysis. Preparation of KBr pellets with a 13 mm die and a hydraulic press is the most popular method used for generation of samples for transmission measurements.

    Click to view
  • Quantitative Analysis of Powdered Solids with FTIRATR

    Quantitative Analysis of Powdered Solids with FTIRATR

    The traditional infrared analysis method for powdered samples is the collection of a KBr pellet spectrum of an aliquot of the powdered sample. However, preparation of KBr pellets requires some skill, especially for quantitative analyses.

    Click to view